Home > Buy Now > Heart Rate Monitor > Color Doppler Ultrasound System
 


Ag T.S.S.
 
icon Products

line

icon Company Profile
icon Selling Leads

line

 
Contact us
Ag T.S.S.
[UAE]
Address:
salam street abu dhabi abu dhabi 48542 UAE
Phone:
971-50-7226052
Contact name:
moh alabed , sales manager
Inquire now










Ag T.S.S.



 
Products

Color Doppler Ultrasound System

Inquire now

Color Doppler Ultrasound System

Click to enlarge image


It is color Doppler ultrasonic diagnostic system is composed of advanced technology of digital color Doppler and wide frequency probe, internet applications system with general measuring function, kinds of leading image process technology, which reaches to leading level in the world. It is whole-body applied digital color ultrasonic diagnosis system of Haiying ultrasonic family with clear image.
Features:

Applications:

  • Abdominal
  • Small Parts  
  • Obstetrics
  • Gynecological
  • Cerebrovascular
  • Peripheral Vascular
  • Cardiac



Imaging Modes:

  • 2D
  • Color Doppler
  • Power Doppler
  • Pulsed Wave Doppler
  • M Mode 
  • Dual Image Mode
  • Duplex, 2D & PW Doppler
  • Triplex, 2D, Color & PW Doppler


System Description:

  • The system is a 128 channel, high resolution ultrasound imaging system with patented Adaptive Focusing which enables high performance ultrasound imaging from 2MHz to 10MHz.

  • Each transducer has three imaging frequencies and two or three Doppler frequencies available.

  • The system has sophisticated report generating capabilities for OB, Vascular, Cardiac, Gynecology and Urology.

  • This PC based system can store images and reports to disk. Images and report can be copied to external media. HTML versions of reports can easily be copied, emailed and viewed by any Internet Browser.

  • The system provides multiple application specific presets for each probe. Custom presets can be generated by the user.

  • Windows 2000 Professional Operating System enables support of a wide range of peripherals and is readily upgraded with software enhancements.



Hardware and Software:

  • 128 Element Linear and Curved Arrays
  • 2 Transducers can be connected electronically selectable
  • Receiver Dynamic Range > 125dB
  • Total Dynamic Range > 150dB
  • Display Dynamic Range > 70dB
  • Eight Transmit Focal Zones for high resolution throughout the image
  • Continuous dynamic focusing on receive
  • Center frequency range from 2.5MHz to 9MHz (band edge from 1.5MHz to 12MHz)
  • Multi-frequency operation for all probes
  • B Mode Imaging frame rates up to 34 frames per second
  • B Mode line density up to 512 lines
  • Field of View (FOV), variable, up to 25 cm in five steps
  • Variable transmit power and variable image gain
  • Slide pot TGC controls

 

  • Cine Loop:
    • Stores up to 256 frames of B & W or Color images (with optional 512MB memory, 128 frames standard)
    • Trackball control of frame-by-frame image selection
    • Controls for cine play back
    • Controls for trimming
    • Cine loops can be saved and retrieved as part of patient record


  • Measurement capability in B Mode:
    • Distance
    • Area by ellipse
    • Area by trace
    • Curve length
    • Volume (required two images)
    • Angle


  • Full image annotation capabilities including:

    • Text entry and editing
    • Pre-programmed vocabulary (user definable)
    • Arrows and pointers
    • Body marks that cover many applications and orientations.



M Mode:

  • B Mode & M Mode display
  • Full screen M Mode display
  • Variable scroll speed 2, 3, 4, 5, 6, 8 seconds
  • User adjustable M Mode line
  • Time, velocity, acceleration, Heart Rate measurements
  • Variable Dynamic Range and Persistence



PW Doppler:

  • Duplex (simultaneous) 2D and Doppler
  • Triplex mode, 2D, Color & PW
  • Steered mode for linear arrays
  • Wide range of velocities (PRFs)
  • Variable wall filters
  • Adjustable gate size from 1 to 7 mm
  • Doppler angle correction for velocity measurements
  • Baseline shift and invert functions
  • Variable spectral sweep speeds
  • Automatic mean and peak velocity traces
  • Variable gray maps
  • Measurement capability in PW Mode: Time, Velocity, Acceleration



Color Doppler Imaging:

  • Region of Interest (ROI), size and position variable
  • Steered Color with linear arrays
  • Variable wall filters
  • Variable Color priority
  • Multiple Color maps
  • Variable Color frame rate
  • Velocity and power displays
  • Variable color persistence
  • Color invert



Power Doppler Imaging:

  • Region of Interest (ROI), size and position variable
  • Steered color with linear arrays
  • Variable wall filters
  • Variable Color priority
  • Multiple Color maps
  • Variable Color frame rate
  • Variable color persistence



Calculation Packages:

All measurement packages support a powerful Worksheet capability that enables review and manipulation of measurement information.

Obstetrics Measurements:

  • Calculation of Estimated Gestational Age (EGA) based upon: AC, BPD, BD, CRL, FL, GSD, HC, HL, MAD, OFD, TL, UL
  • Calculation of Estimated Fetal Weight (EFW)
  • Calculation of growth parameter ratios
  • Graphic display of statistical growth charts
  • Biophysical Score report
  • Structural Report



Cardiac Measurements:

  • Cardiac index
  • Cardiac output
  • LV end-diastolic volume
  • LV end-systolic volume
  • Ejection fraction
  • Stroke index
  • Stroke volume
  • IVS/LVPW ratio
  • Aortic valve pressure gradient
  • Aortic pressure half time
  • Aortic valve area
  • Mitral valve area
  • Left ventricular outflow tract pressure gradient



Vascular Measurements:

  • Time Average Mean Velocity (TAM)
  • Time Average Max Velocity (TAMX)
  • Pulsatility Index (PI)
  • Resistive Index (RI)
  • Peak Systolic Velocity (PSV)
  • End Diastolic Velocity (EDV)
  • S/D Ratio (PSV/EDV)
  • PSV_ICA/PSV_CCA
  • Velocity Ratio (Velocity 1 / Velocity 2)
  • % Stenosis by Diameter
  • % Stenosis by Area



Focusing:

Transmitting focusing 8 ranges, receiving continuous focusing.

Display Parameter:

Acoustic power, total gain, dynamic range, TGC curve, gain of Doppler, pulse repetition frequency, wall-filtering ratio.

Image Process:

Colorful map, frame average processing, angle adjustment and wall filter.

Gray 256:

  • Image Storage and playback of 128 continuous image


    Standard Configuration:
    Main unit
    15RGB color monitor, resolution 1024*768
    3.5MHz 60R65D multi-frequency convex probe
    7.8MHz38L multi-frequency linear probe

 




Inquire now


   
 
 

Related products from premium suppliers on EC21